ADSORPSI NIKEL DAN KOBALT PADA RESIN PENUKAR ION LEWATIT MONOPLUS TP 207 XL DALAM BEBERAPA LARUTAN SULFAT
Abstract
Resin penukar ion Lewatit Monoplus TP 207 XL adalah salah satu resin untuk memisahkan logam dari larutan hasil pelindian bijih nikel laterit. Resin ini tahan terhadap abrasi, dapat digunakan pada suhu diatas suhu kamar, memiliki kelarutan yang rendah dalam larutan hasil leaching sehingga dapat digunakan berulang-ulang. Tulisan ini membahas kinetika proses adsorpsi nikel dan kobalt pada resin penukar ion Lewatit Monoplus TP 207 XL dalam beberapa larutan nikel dan kobalt sintetik dengan pH 3, 4, dan 5 pada suhu kamar, 40 °C, dan50°C. Hasil dari percobaan menunjukkan bahwa dalam larutan nikel sulfat dan kobalt sulfat sintetik pH 5, persen adsorpsi nikel dan kobalt masing-masing dapat mencapai 92,19% dan 97,12% bila adsorpsinya dilakukan pada suhu 50 °C. Berdasarkan studi kinetika yang telah dilakukan, laju adsorpsi pada resin saat awal proses ( ≤ 2 jam) cenderung terkendali oleh laju difusi ion-ion melalui lapis difusi dalam fluida. Hasil percobaan menunjukka n pH dan suhu larutan berpengaruh pada persen adsorpsi nikel dan kobalt dan resin lebih sesuai untuk adsorpsi logam-logam ini secara bersamaan, karena tidak cukup selektif untuk memisahkan keduanya. Kemungkinan penggunaan resin ini untuk mengadsorpsi nikel dan kobalt dari beberapa larutan hasil pelindian nikel laterit kadar rendah yang telah dikurangi kandungan ion besinya juga disajikan dalam tulisan ini.
Abstract
Lewatit Monoplus TP 207 XL ion exchange resin has a function to separate metal from nickel ore laterite in leaching solution. This resin has good wear ability and low solubility inside of solution after leaching process, therefore can be used at elevated temperature frequently. This study concern on kinetic of nickel and cobalt absorption of Lewatit Monoplus TP 207 XL ion exchange resin in nickel solution and synthetic cobalt, with potential hydrogen various around 3,4 and 5 at room temperature of 40 °C and 50 °C. Result shows that nickel and cobalt adsorption percentage can be obtained approximately around 92.19% and 97.12%, respectively, in nickel sulfide solution and 5 potential hydrogen of synthetic cobalt at temperature 50 °C. Based on kinetic study which has been done, absorption rate of resin at the first process (≤ 2 h) effected by ions diffusion rate through diffusion layer in the fluid. Result shows that potential hydrogen and solution temperature affect in nickel and cobalt absorption percentages, and also resin more appropriate to absorb these metals simultaneously, due to difficulty to separate of them. This study also shows possibility to using this resin for absorption nickel and cobalt in various solutions which is obtained from low nickel laterite with low ferrous ions after leaching process.
Keywords
Full Text:
PDF (Bahasa Indonesia)References
Kunin, R., Ion Exchange Resin , Second Edition, John Wiley and Son, Inc., New York.
Zaimawati, Z . 2005. Development of Resin in Pulp Process for Recovery Nickel and Cobalt from Laterite Leach Slurries , PhD Thesis, Murdoch Univ. WA .
Habashi, F.1970. Principle Of Extractive Metallurgy , Volume 2 (Hydrometallurgy), Gordon and Research, Science Publisher, Inc, New York.
Metal Winning by Hydrometallu rgy, Lewatit, Bayer Chamicals.